%{tishi_zhanwei}%

SHR-650S intelligent constant temperature cement hydration heat tester

Price


This instrument is designed according to the relevant provisions of the national standard GB/T12959-2008 "Method for Determination of Heat of Hydration of Cement". It is suitable for the determination of heat of hydration at any hydration age of medium-heat Portland cement, low-heat slag Portland cement, ordinary Portland cement, slag Portland cement, pozzolan Portland cement, fly ash Portland cement, etc. This instrument can also be used for other cement varieties when the solution heat method is specified to measure the heat of hydration.

重量

Quantity
-
+

Inventory

隐藏域元素占位

  • Description
    • Commodity name: SHR-650S intelligent constant temperature cement hydration heat tester

    This instrument is designed according to the relevant provisions of the national standard GB/T12959-2008 "Method for Determination of Heat of Hydration of Cement". It is suitable for the determination of heat of hydration at any hydration age of medium-heat Portland cement, low-heat slag Portland cement, ordinary Portland cement, slag Portland cement, pozzolan Portland cement, fly ash Portland cement, etc. This instrument can also be used for other cement varieties when the solution heat method is specified to measure the heat of hydration.

    Purpose and principle

        This instrument is designed according to the relevant provisions of the national standard GB/T12959-2008 "Method for Determination of Heat of Hydration of Cement". It is suitable for the determination of heat of hydration at any hydration age of medium-heat Portland cement, low-heat slag Portland cement, ordinary Portland cement, slag Portland cement, pozzolan Portland cement, fly ash Portland cement, etc. This instrument can also be used for other cement varieties when the solution heat method is specified to measure the heat of hydration.

     

    Main technical specifications

    1. Tank temperature. 20℃±0.1℃

    2. Vacuum bottle volume. about 650ml

      The cooling rate is ≤0.001°C/min after it is filled with water 5°C higher than room temperature and left to stand for 30 minutes.

    3. The speed of the acid stirring rod. 400~500rpm

    4. Power supply. 2500W/AC220V/50Hz

    5. High precision electronic thermometer

        Differential range. 0~100℃

        Graduation value. 0.001°C

    6. Instrument dimensions (length × width × height mm)

        host. 810×500×760

        Constant temperature unit. 730×420×500

    7. Net weight of the instrument. 130kg

Message